Specification of Ica Ups St623b
We are an official authorized dealer who sold the product UPS ICA.
ICA UPS 1200VA ST623B selling.
We also sell UPS ICA Type Other ST Series.
ICA ST SERIES
-ST 623B 1200VA
-ST 1023B 2000VA
-ST 531C 1000VA
-ST 831C 1600VA
-ST 1231C 2400VA
-ST 1631C 3200VA
The following specifications UPS ICA ST series:
Description: UPS ST623B
Capacity: 1200VA/600 W
AC Voltage: 160-250 V
AC Frequency: 50 ± 3 Hz
AC Protection: 6.3 A
DC Voltage: 24 V
DC INT Battery: 2 x 12 V, 7 Ah
DC Protection: FUSE
CHG Topology: CONSTANT VOLTAGE
CHG Floating Voltage: 27.2 V
INV Waveform: SINEWAVE
INV Distorsion:< 3%="">
INV Topology: PULSE WIDTH MODULATION (PWM)
INV Voltage: 220 V ± 5%
INV Frequency: 50 Hz ± 1%
INV: ± 80% Efficiency
Transfer Time: Back Up Time: 10 min
AC Input Low/Buzer Fail: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer AC Input High: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS
Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS
Opera Temp: 0-40 ° C
Dimension (DxWxH): 425 x140 x 200 mm
Weight: 13.2 Kg
Description: UPS ST1023B
Capacity: 2000 VA/1000 W
AC Voltage: 160-250 V
AC Frequency: 50 ± 3 Hz
AC Protection: 10 A
DC Voltage: 36 V
DC INT Battery: 3 x 12 V, 7 Ah
DC Protection: FUSE
CHG Topology: CONSTANT VOLTAGE
CHG Floating Voltage: 25.4 V
INV Waveform: SINEWAVE
INV Distorsion:< 3%="">
INV Topology: PULSE WIDTH MODULATION (PWM)
INV Voltage: 220 V ± 5%
INV Frequency: 50 Hz ± 1%
INV: ± 80% Efficiency
Transfer Time: Back Up Time: 10 min BZR AC Input Low/Fail
AC Input Low/Buzer Fail: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer AC Input High: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS
BuzerBattery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS
Opera Temp: 0-40 ° C
Dimension (DxWxH): 505 x 140 x 200 mm
Weight: 10.7 Kg
Description: UPS ST531C
Capacity: 1000 VA/500 W
AC Voltage: 160-250 V
AC Frequency: 50 ± 3 Hz
AC Protection: 5 A
DC Voltage: 24 V
DC INT Battery: 2 x 12 V, 7 Ah
DC Protection: FUSE
CHG: Topology SWITCHING REGULATION
CHG Floating Voltage: 27.2 V
INV Waveform: SINEWAVE
INV Distorsion:< 3%="">
INV Topology: PULSE WIDTH MODULATION (PWM)
INV Voltage: 220 V ± 2%
INV Frequency: 50 Hz ± 1%
INV Efficiency: 85% >
Transfer Time AC Fail: 0 ms
Transfer Time: 2 STS ms Inverter to Bypass
Inverter to Bypass: ZERO CROSSING BYPASS TO INVERTER
Back Up Time: 10 min
AC Input Low/Buzer Fail: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS
Opera Temp: 0-40 ° C
Dimension (DxWxH): 395 x 190 x 290 mm
Weight: 14.5 Kg
Description: UPS ST831C
Capacity: 1600 VA/800 W
AIR CONDITIONINGVoltage: 160-250 V
AC Frequency: 50 ± 3 Hz
AC Protection: 7 A
DC Voltage: 48 V
DC INT Battery: 4 x 12 V, 7 Ah
DC Protection: FUSE
CHG: Topology SWITCHING REGULATION
CHG Floating Voltage: 33.8 V
INV Waveform: SINEWAVE
INV Distorsion:< 3%="">
INV Topology: PULSE WIDTH MODULATION (PWM)
INV Voltage: 220± 2% V
INV Frequency: 50 Hz ± 1%
INV Efficiency: 85% >
Transfer Time AC Fail: 0 ms
Transfer Time: 2 STS ms Inverter to Bypass
Inverter to Bypass: ZERO CROSSING BYPASS TO INVERTER
Back Up Time: 10 min
AC Input Low/Buzer Fail: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS
Opera Temp: 0-40 ° C
Dimension (DxWxH): 395 x 190 x 290 mm
Weight: 19.5 Kg
Description: UPS ST1231C
Capacity: 2400 VA/1200 W
AC Voltage: 160-250 V
AC Frequency: 50 ± 3 Hz
AC Protection: 10 A
DC Voltage: 72 V
DC INT Battery: 6 x 12 V, 7 Ah
DC Protection: FUSE
CHG: Topology SWITCHING REGULATION
CHG FloaTing: 50.7 Voltage V
INV Waveform: SINEWAVE
INV Distorsion:< 3%="">
INV Topology: PULSE WIDTH MODULATION (PWM)
INV Voltage: 220 V ± 2%
INV Frequency: 50 Hz ± 1%
INV Efficiency: 85% >
Transfer Time AC Fail: 0 ms
Transfer Time: 2 STS ms Inverter to Bypass
Inverter to Bypass: ZERO CROSSING BYPASS TO INVERTER
Back Up Time:10 min
AC Input Low/Buzer Fail: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS
Opera Temp: 0-40 ° C
Dimension (DxWxH): 510 x 190 x 330 mm
Weight: 28 Kg
Description: UPS ST1631C
Capacity: 3200/1600 W VA
AC Voltage: 160-250 V
AC Frequency: 50 ± 3 Hz
AC Protection:15 A
DC Voltage: 96 V
DC INT Battery: 8 x 12 V, 7 Ah
DC Protection: FUSE
CHG: Topology SWITCHING REGULATION
CHG Floating Voltage: 50.7 V
INV Waveform: SINEWAVE
INV Distorsion:< 3%="">
INV Topology: PULSE WIDTH MODULATION (PWM)
INV Voltage: 220 V ± 2%
INV Frequency: 50 Hz ± 1%
INV Efficiency: 85% >
TRAnsfer AC Fail Time: 0 ms
Transfer Time: 2 STS ms Inverter to Bypass
Inverter to Bypass: ZERO CROSSING BYPASS TO INVERTER
Back Up Time: 10 min
AC Input Low/Buzer Fail: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS
Opera Temp: 0-40 ° C
Dimension (DxWxH): 510 x 190 x 330 mm
Weight: 33 Kg
(The price listed in the price column, not the actual price)
Contact us immediately to get information about types, prices and the latest stock.
Pt. Trkomindo Main Charites
Email: marketing@trikomkharisma.com
Tags:
ica ups distributor indonesia jakarta mangga dua authorized dealer for master d