sql

Ica Ups Sin3100c

Rp. CALL
Last Updated
21 Sep 2021
Country Origin
Indonesia
Minimum Order
1 Kg
Subcategory
Ups Ica

Specification of Ica Ups Sin3100c

We are an official authorized dealer who sold the product UPS ICA.

ICA UPS 5KVA SIN3100C selling.

We also sell Other ICA UPS SIN Series.


ICA TP SERIES

-SIN 1100C 1600VA

-SIN 1500C 2500VA

-SIN 2100C 3100VA

-SIN 3100C 5KVA

-SIN 5100C 8KVA

-SIN 5100C3 8KVA

-SIN 7501C1 10KVA

-SIN 7501C3 10KVA

-SIN 1002C1 12.5 KVA

-SIN 1002C3 12.5 KVA

-SIN 1502C1 18KVA

-SIN 1502C3 18KVA

-SIN 2002C1 25KVA

-SIN 2002C3 25KVA

 

Here's the specs the ICA UPS SIN series:


Description: UPS SIN3100C

Capacity: 5000 VA/3250 W

AC Voltage: 185-250 V

AC Frequency: 50 ± 5% Hz

AC Protection: NO FUSE BREAKER

Voltag DCe: 192 V

DC INT Battery: 4 x 12 V, 7 Ah

DC Protection: NO FUSE BREAKER

CHG: Topology SWITCHING REGULATION

CHG Floating Voltage: 217.6 V

INV Waveform: SINUSOIDA

INV Distorsion:< 3%="">

INV Topology: PULSE WIDTH MODULATION (PWM)

INV Voltage: 220 V ± 2%

INV Frequency: 50 Hz ± 1%

INV Efficiency: 85% >

Transfer Teame When AIR CONDITIONING In Loss: 0 ms

Static Transfer Switches: 2 ms From the Inverter to Bypass, 0 ms Back To Inverter

Back Up Time: 10 min

Buzer UPS In Bypass Condition: INTERMITTENT SOUND WITH 30 SECONDS INTERVALS

Buzer AIR CONDITIONING In Abnormal: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL

Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS

Opera Temp: 0-40 ° C

Dimension (DxWxH): 630 x 265 x 690 mm

Weight: 110 Kg

 

 


Description: UPS SIN5100C

Capacity: 8000 VA/5200 W

AC Voltage: SINGLE PHASE, 3 WIRE 220 V

AC Frequency: 50 ± 5% Hz

AC Protection: NO FUSE BREAKER

DC Voltage: 192 V

DC INT Battery: 4 x 12 V, 2 Ah

DC Protection: NO FUSE BREAKER

CHG: Topology SWITCHING REGULATION

CHG FloV ating Voltage: 217.6

INV Waveform: SINUSOIDA

INV Distorsion:< 3%="">

INV Topology: PULSE WIDTH MODULATION (PWM)

INV Voltage: 220 V ± 2%

INV Frequency: 50 Hz ± 1%

INV: ± 85% Efficiency

Transfer Time When AIR CONDITIONING In Loss: 0 ms

Static Transfer Switches: 2 ms From the Inverter to Bypass, 0 ms Back To Inverter

Back Up Time: 10 min

Buzer UPSIn the Bypass Condition: INTERMITTENT SOUND WITH 30 SECONDS INTERVALS

Buzer AIR CONDITIONING In Abnormal: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL

Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS

Opera Temp: 0-40 ° C

Dimension (DxWxH): 648 x 360 x 846 mm

Weight: 240 Kg

 

 


Description: UPS SIN5100C3

Capacity: 8000 VA/5200 W

AC Voltage:THREE PHASE, 4 WIRE 380 V

AC Frequency: 50 ± 5% Hz

AC Protection: NO FUSE BREAKER

DC Voltage: 192 V

DC INT Battery: 4 x 12 V, 2 Ah

DC Protection: NO FUSE BREAKER

CHG: Topology SWITCHING REGULATION

CHG Floating Voltage: 217.6 V

INV Waveform: SINUSOIDA

INV Distorsion:< 3%="">

INV Topology: PULSE WIDTH MODULATION (PWM)

INV Voltage: 220 V ± 2%

INV Frequency: 50 Hz ± 1%

INV: ± 85% Efficiency

Transfer Time When AIR CONDITIONING In Loss: 0 ms

Static Transfer Switches: 2 ms From the Inverter to Bypass, 0 ms Back To Inverter

Back Up Time: 10 min

Buzer UPS In Bypass Condition: INTERMITTENT SOUND WITH 30 SECONDS INTERVALS

Buzer AIR CONDITIONING In Abnormal: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL

Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS

Opera Temp: 0-40 ° C

Dimension (DxWxH): 648 x 360 x 846 mm

Weight: 240 Kg

 

 

Description: UPS SIN7501C1

Capacity: 10000 VA/6500 W

AC Voltage: SINGLE PHASE, 3 WIRE 220 V

AC Frequency: 50 ± 5% Hz

AC Protection: NO FUSE BREAKER

DC Voltage: 192 V

DC INT Battery: 4x 12 V 17 Ah

DC Protection: NO FUSE BREAKER

CHG: Topology SWITCHING REGULATION

CHG Floating Voltage: 217.6 V

INV Waveform: SINUSOIDA

INV Distorsion:< 3%="">

INV Topology: PULSE WIDTH MODULATION (PWM)

INV Voltage: 220 V ± 2%

INV Frequency: 50 Hz ± 1%

INV: ± 85% Efficiency

Transfer Time When AIR CONDITIONING In Loss: 0 ms

Static TranSFER Switches: 2 ms From the Inverter to Bypass, 0 ms Back To Inverter

Back Up Time: 10 min

Buzer UPS In Bypass Condition: INTERMITTENT SOUND WITH 30 SECONDS INTERVALS

Buzer AIR CONDITIONING In Abnormal: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL

Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS

Opera Temp: 0-40 ° C

Dimension (DxWxH): 765 x 595 x 1120 mm

Weight: 307 Kg

 

 

 

Description: UPS SIN7501C3

Capacity: 10000 VA/6500 W

AC Voltage: THREE PHASE, 4 WIRE 380 V

AC Frequency: 50 ± 5% Hz

AC Protection: NO FUSE BREAKER

DC Voltage: 192 V

DC INT Battery: 4 x 12 V 17 Ah

DC Protection: NO FUSE BREAKER

CHG: Topology SWITCHING REGULATION

CHG Floating Voltage: 217.6 V

INV WavefoRM: SINUSOIDA

INV Distorsion:< 3%="">

INV Topology: PULSE WIDTH MODULATION (PWM)

INV Voltage: 220 V ± 2%

INV Frequency: 50 Hz ± 1%

INV: ± 85% Efficiency

Transfer Time When AIR CONDITIONING In Loss: 0 ms

Static Transfer Switches: 2 ms From the Inverter to Bypass, 0 ms Back To Inverter

Back Up Time: 10 min

Buzer UPS In Bypass Condition: INTERMITTENT SOUND WITH 30 SECONDS INTERVALS

Buzer AIR CONDITIONING In Abnormal: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL

Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS

Opera Temp: 0-40 ° C

Dimension (DxWxH): 765 x 595 x 1120 mm

Weight: 307 Kg

 

 


Description: UPS SIN1002C1

Capacity: 12500 VA/8125 W

AC Voltage: SINGLE PHASE, 3 WIRE 220 V

AIR CONDITIONING Frequency: 50 ± 5% Hz

AC Protection: NO FUSE BREAKER

DC Voltage: 192 V

DC INT Battery: 4 x 12 V 24 Ah

DC Protection: NO FUSE BREAKER

CHG: Topology SWITCHING REGULATION

CHG Floating Voltage: 217.6 V

INV Waveform: SINUSOIDA

INV Distorsion:< 3%="">

INV Topology: PULSE WIDTH MODULATION (PWM)

INV Voltage: 220 V ± 2%

F INVrequency: ± 1% 50 Hz

INV: ± 85% Efficiency

Transfer Time When AIR CONDITIONING In Loss: 0 ms

Static Transfer Switches: 2 ms From the Inverter to Bypass, 0 ms Back To Inverter

Back Up Time: 10 min

Buzer UPS In Bypass Condition: INTERMITTENT SOUND WITH 30 SECONDS INTERVALS

Buzer AIR CONDITIONING In Abnormal: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL

Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVAL

Opera Temp: 0-40 ° C

Dimension (DxWxH): 765 x 595 x 1120 mm

Weight: 364 Kg

 

 

Description: UPS SIN1002C3

Capacity: 12500 VA/8125 W

AC Voltage: THREE PHASE, 4 WIRE 380 V

AC Frequency: 50 ± 5% Hz

AC Protection: NO FUSE BREAKER

DC Voltage: 192 V

DC INT Battery: 4 x 12 V 24 Ah

DC Protection:NO FUSE BREAKER

CHG: Topology SWITCHING REGULATION

CHG Floating Voltage: 217.6 V

INV Waveform: SINUSOIDA

INV Distorsion:< 3%="">

INV Topology: PULSE WIDTH MODULATION (PWM)

INV Voltage: 220 V ± 2%

INV Frequency: 50 Hz ± 1%

INV: ± 85% Efficiency

Transfer Time When AIR CONDITIONING In Loss: 0 ms

Static Transfer Switches: 2 ms From the Inverter to Bypass, 0 ms Back To Inverter

Back Up Time: 10 min

Buzer UPS In Bypass Condition: INTERMITTENT SOUND WITH 30 SECONDS INTERVALS

Buzer AIR CONDITIONING In Abnormal: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL

Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS

Opera Temp: 0-40 ° C

Dimension (DxWxH): 765 x 595 x 1120 mm

Weight: 364 Kg

 

 


Description: UPS SIN1502C1

Capacity: 18000 11700 W/VA

AC Voltage: SINGLE PHASE, 3 WIRE 220 V

AC Frequency: 50 ± 5% Hz

AC Protection: NO FUSE BREAKER

DC Voltage: 192 V

DC INT Battery: 4 x 12 V 24 Ah

DC Protection: NO FUSE BREAKER

CHG: Topology SWITCHING REGULATION

CHG Floating Voltage: 217.6 V

INV Waveform: SINUSOIDA

INV Distorsion:< 3%="">

INV Topology: PULSE WIDTH MODULATION (PWM)

INV Voltage: 220 V ± 2%

INV Frequency: 50 Hz ± 1%

INV: ± 85% Efficiency

Transfer Time When AIR CONDITIONING In Loss: 0 ms

Static Transfer Switches: 2 ms From the Inverter to Bypass, 0 ms Back To Inverter

Back Up Time: 10 min

Buzer UPS In Bypass Condition: INTERMITTENT SOUND WITH 30 SECONDS INTERVALS

Buzer AIR CONDITIONING In Abnormal: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL

Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS

Opera Temp: 0-40 ° C

Dimension (DxWxH): 765 x 595 x 1120 mm

Weight: 383 Kg

 

 


Description: UPS SIN1502C3

Capacity: 18000 11700 W/VA

AC Voltage: THREE PHASE, 4 WIRE 380 V

AC Frequency: 50 ± 5% Hz

AC Protection: NO FUSE BREAKER

DC Voltage: 192 V

DC INT Battery: 4 x 12 V 24 Ah

DC Protection: NO FUSE BREAKER

CHG: Topology SWITCHING REGULATION

CHG Floating Voltage: 217.6 V

INV Waveform: SINUSOIDA

INV Distorsion:< 3%="">

INV Topology: PULSE WIDTH MODULATION (PWM)

INV Voltage: 220 V ± 2%

INV Frequency: 50 Hz ± 1%

INV Efficiency: ± 85%

Transfer Time When AIR CONDITIONING In Loss: 0 ms

Static Transfer Switches: 2 ms From the Inverter to Bypass, 0 ms Back To Inverter

Back Up Time: 10 min

Buzer UPS In Bypass Condition: INTERMITTENT SOUND WITH 30 SECONDS INTERVALS

Buzer AIR CONDITIONING In Abnormal: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL

Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS

Opera Temp: 0-40 ° CBr/> Dimension (DxWxH): 765 x 595 x 1120 mm

Weight: 383 Kg

 

 


Description: UPS SIN2002C1

Capacity: 25000 VA/16250 W

AC Voltage: SINGLE PHASE, 3 WIRE 220 V

AC Frequency: 50 ± 5% Hz

AC Protection: NO FUSE BREAKER

DC Voltage: 192 V

DC INT Battery: 4 x 12 V, 38 Ah

DC Protection: NO FUSE BREAKER

CHG Topology: SWITCHING REGULATION

CHG Floating Voltage: 217.6 V

INV Waveform: SINUSOIDA

INV Distorsion:< 3%="">

INV Topology: PULSE WIDTH MODULATION (PWM)

INV Voltage: 220 V ± 2%

INV Frequency: 50 Hz ± 1%

INV: ± 85% Efficiency

Transfer Time When AIR CONDITIONING In Loss: 0 ms

Static Transfer Switches: 2 ms From the Inverter to Bypass, 0 ms Back To Inverter

Back Up Time: 10 min

Buzer UPS In Bypass Condition: INTERMITTENT SOUND WITH 30 SECONDS INTERVALS

Buzer AIR CONDITIONING In Abnormal: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL

Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS

Opera Temp: 0-40 ° C

Dimension (DxWxH): 870 x 595 x 1315 mm

Weight: 490 Kg

 

 


Description: UPS SIN2002C3

Capacity:25000 VA/16250 W

AC Voltage: THREE PHASE, 4 WIRE 380 V

AC Frequency: 50 ± 5% Hz

AC Protection: NO FUSE BREAKER

DC Voltage: 192 V

DC INT Battery: 4 x 12 V, 38 Ah

DC Protection: NO FUSE BREAKER

CHG: Topology SWITCHING REGULATION

CHG Floating Voltage: 217.6 V

INV Waveform: SINUSOIDA

INV Distorsion:< 3%="">

INV Topology: PULSE WIDTH MODULATION (PWM)

INV Voltage: 220 V ± 2%

INV Frequency: 50 Hz ± 1%

INV: ± 85% Efficiency

Transfer Time When AIR CONDITIONING In Loss: 0 ms

Static Transfer Switches: 2 ms From the Inverter to Bypass, 0 ms Back To Inverter

Back Up Time: 10 min

Buzer UPS In Bypass Condition: INTERMITTENT SOUND WITH 30 SECONDS INTERVALS

Buzer AIR CONDITIONING In Abnormal: INTERMITTENT SOUNDWith 4 SECONDS INTERVAL

Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS

Opera Temp: 0-40 ° C

Dimension (DxWxH): 870 x 595 x 1315 mm

Weight: 490 Kg

 

 

(The price listed in the price column, not the actual price)

Contact us immediately to get information about types, prices and the latest stock.

Pt. Trkomindo Main Charites


Email

Lihat Selengkapnya

Untuk keterangan lebih lanjut, silahkan download PDF ini :

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Request a Quote
Produk Siap di Pesan
Rp 0
1