Specification of Ica Ups Sin3100c
We are an official authorized dealer who sold the product UPS ICA.
ICA UPS 5KVA SIN3100C selling.
We also sell Other ICA UPS SIN Series.
ICA TP SERIES
-SIN 1100C 1600VA
-SIN 1500C 2500VA
-SIN 2100C 3100VA
-SIN 3100C 5KVA
-SIN 5100C 8KVA
-SIN 5100C3 8KVA
-SIN 7501C1 10KVA
-SIN 7501C3 10KVA
-SIN 1002C1 12.5 KVA
-SIN 1002C3 12.5 KVA
-SIN 1502C1 18KVA
-SIN 1502C3 18KVA
-SIN 2002C1 25KVA
-SIN 2002C3 25KVA
Here's the specs the ICA UPS SIN series:
Description: UPS SIN3100C
Capacity: 5000 VA/3250 W
AC Voltage: 185-250 V
AC Frequency: 50 ± 5% Hz
AC Protection: NO FUSE BREAKER
Voltag DCe: 192 V
DC INT Battery: 4 x 12 V, 7 Ah
DC Protection: NO FUSE BREAKER
CHG: Topology SWITCHING REGULATION
CHG Floating Voltage: 217.6 V
INV Waveform: SINUSOIDA
INV Distorsion:< 3%="">
INV Topology: PULSE WIDTH MODULATION (PWM)
INV Voltage: 220 V ± 2%
INV Frequency: 50 Hz ± 1%
INV Efficiency: 85% >
Transfer Teame When AIR CONDITIONING In Loss: 0 ms
Static Transfer Switches: 2 ms From the Inverter to Bypass, 0 ms Back To Inverter
Back Up Time: 10 min
Buzer UPS In Bypass Condition: INTERMITTENT SOUND WITH 30 SECONDS INTERVALS
Buzer AIR CONDITIONING In Abnormal: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS
Opera Temp: 0-40 ° C
Dimension (DxWxH): 630 x 265 x 690 mm
Weight: 110 Kg
Description: UPS SIN5100C
Capacity: 8000 VA/5200 W
AC Voltage: SINGLE PHASE, 3 WIRE 220 V
AC Frequency: 50 ± 5% Hz
AC Protection: NO FUSE BREAKER
DC Voltage: 192 V
DC INT Battery: 4 x 12 V, 2 Ah
DC Protection: NO FUSE BREAKER
CHG: Topology SWITCHING REGULATION
CHG FloV ating Voltage: 217.6
INV Waveform: SINUSOIDA
INV Distorsion:< 3%="">
INV Topology: PULSE WIDTH MODULATION (PWM)
INV Voltage: 220 V ± 2%
INV Frequency: 50 Hz ± 1%
INV: ± 85% Efficiency
Transfer Time When AIR CONDITIONING In Loss: 0 ms
Static Transfer Switches: 2 ms From the Inverter to Bypass, 0 ms Back To Inverter
Back Up Time: 10 min
Buzer UPSIn the Bypass Condition: INTERMITTENT SOUND WITH 30 SECONDS INTERVALS
Buzer AIR CONDITIONING In Abnormal: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS
Opera Temp: 0-40 ° C
Dimension (DxWxH): 648 x 360 x 846 mm
Weight: 240 Kg
Description: UPS SIN5100C3
Capacity: 8000 VA/5200 W
AC Voltage:THREE PHASE, 4 WIRE 380 V
AC Frequency: 50 ± 5% Hz
AC Protection: NO FUSE BREAKER
DC Voltage: 192 V
DC INT Battery: 4 x 12 V, 2 Ah
DC Protection: NO FUSE BREAKER
CHG: Topology SWITCHING REGULATION
CHG Floating Voltage: 217.6 V
INV Waveform: SINUSOIDA
INV Distorsion:< 3%="">
INV Topology: PULSE WIDTH MODULATION (PWM)
INV Voltage: 220 V ± 2%
INV Frequency: 50 Hz ± 1%
INV: ± 85% Efficiency
Transfer Time When AIR CONDITIONING In Loss: 0 ms
Static Transfer Switches: 2 ms From the Inverter to Bypass, 0 ms Back To Inverter
Back Up Time: 10 min
Buzer UPS In Bypass Condition: INTERMITTENT SOUND WITH 30 SECONDS INTERVALS
Buzer AIR CONDITIONING In Abnormal: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS
Opera Temp: 0-40 ° C
Dimension (DxWxH): 648 x 360 x 846 mm
Weight: 240 Kg
Description: UPS SIN7501C1
Capacity: 10000 VA/6500 W
AC Voltage: SINGLE PHASE, 3 WIRE 220 V
AC Frequency: 50 ± 5% Hz
AC Protection: NO FUSE BREAKER
DC Voltage: 192 V
DC INT Battery: 4x 12 V 17 Ah
DC Protection: NO FUSE BREAKER
CHG: Topology SWITCHING REGULATION
CHG Floating Voltage: 217.6 V
INV Waveform: SINUSOIDA
INV Distorsion:< 3%="">
INV Topology: PULSE WIDTH MODULATION (PWM)
INV Voltage: 220 V ± 2%
INV Frequency: 50 Hz ± 1%
INV: ± 85% Efficiency
Transfer Time When AIR CONDITIONING In Loss: 0 ms
Static TranSFER Switches: 2 ms From the Inverter to Bypass, 0 ms Back To Inverter
Back Up Time: 10 min
Buzer UPS In Bypass Condition: INTERMITTENT SOUND WITH 30 SECONDS INTERVALS
Buzer AIR CONDITIONING In Abnormal: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS
Opera Temp: 0-40 ° C
Dimension (DxWxH): 765 x 595 x 1120 mm
Weight: 307 Kg
Description: UPS SIN7501C3
Capacity: 10000 VA/6500 W
AC Voltage: THREE PHASE, 4 WIRE 380 V
AC Frequency: 50 ± 5% Hz
AC Protection: NO FUSE BREAKER
DC Voltage: 192 V
DC INT Battery: 4 x 12 V 17 Ah
DC Protection: NO FUSE BREAKER
CHG: Topology SWITCHING REGULATION
CHG Floating Voltage: 217.6 V
INV WavefoRM: SINUSOIDA
INV Distorsion:< 3%="">
INV Topology: PULSE WIDTH MODULATION (PWM)
INV Voltage: 220 V ± 2%
INV Frequency: 50 Hz ± 1%
INV: ± 85% Efficiency
Transfer Time When AIR CONDITIONING In Loss: 0 ms
Static Transfer Switches: 2 ms From the Inverter to Bypass, 0 ms Back To Inverter
Back Up Time: 10 min
Buzer UPS In Bypass Condition: INTERMITTENT SOUND WITH 30 SECONDS INTERVALS
Buzer AIR CONDITIONING In Abnormal: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS
Opera Temp: 0-40 ° C
Dimension (DxWxH): 765 x 595 x 1120 mm
Weight: 307 Kg
Description: UPS SIN1002C1
Capacity: 12500 VA/8125 W
AC Voltage: SINGLE PHASE, 3 WIRE 220 V
AIR CONDITIONING Frequency: 50 ± 5% Hz
AC Protection: NO FUSE BREAKER
DC Voltage: 192 V
DC INT Battery: 4 x 12 V 24 Ah
DC Protection: NO FUSE BREAKER
CHG: Topology SWITCHING REGULATION
CHG Floating Voltage: 217.6 V
INV Waveform: SINUSOIDA
INV Distorsion:< 3%="">
INV Topology: PULSE WIDTH MODULATION (PWM)
INV Voltage: 220 V ± 2%
F INVrequency: ± 1% 50 Hz
INV: ± 85% Efficiency
Transfer Time When AIR CONDITIONING In Loss: 0 ms
Static Transfer Switches: 2 ms From the Inverter to Bypass, 0 ms Back To Inverter
Back Up Time: 10 min
Buzer UPS In Bypass Condition: INTERMITTENT SOUND WITH 30 SECONDS INTERVALS
Buzer AIR CONDITIONING In Abnormal: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVAL
Opera Temp: 0-40 ° C
Dimension (DxWxH): 765 x 595 x 1120 mm
Weight: 364 Kg
Description: UPS SIN1002C3
Capacity: 12500 VA/8125 W
AC Voltage: THREE PHASE, 4 WIRE 380 V
AC Frequency: 50 ± 5% Hz
AC Protection: NO FUSE BREAKER
DC Voltage: 192 V
DC INT Battery: 4 x 12 V 24 Ah
DC Protection:NO FUSE BREAKER
CHG: Topology SWITCHING REGULATION
CHG Floating Voltage: 217.6 V
INV Waveform: SINUSOIDA
INV Distorsion:< 3%="">
INV Topology: PULSE WIDTH MODULATION (PWM)
INV Voltage: 220 V ± 2%
INV Frequency: 50 Hz ± 1%
INV: ± 85% Efficiency
Transfer Time When AIR CONDITIONING In Loss: 0 ms
Static Transfer Switches: 2 ms From the Inverter to Bypass, 0 ms Back To Inverter
Back Up Time: 10 min
Buzer UPS In Bypass Condition: INTERMITTENT SOUND WITH 30 SECONDS INTERVALS
Buzer AIR CONDITIONING In Abnormal: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS
Opera Temp: 0-40 ° C
Dimension (DxWxH): 765 x 595 x 1120 mm
Weight: 364 Kg
Description: UPS SIN1502C1
Capacity: 18000 11700 W/VA
AC Voltage: SINGLE PHASE, 3 WIRE 220 V
AC Frequency: 50 ± 5% Hz
AC Protection: NO FUSE BREAKER
DC Voltage: 192 V
DC INT Battery: 4 x 12 V 24 Ah
DC Protection: NO FUSE BREAKER
CHG: Topology SWITCHING REGULATION
CHG Floating Voltage: 217.6 V
INV Waveform: SINUSOIDA
INV Distorsion:< 3%="">
INV Topology: PULSE WIDTH MODULATION (PWM)
INV Voltage: 220 V ± 2%
INV Frequency: 50 Hz ± 1%
INV: ± 85% Efficiency
Transfer Time When AIR CONDITIONING In Loss: 0 ms
Static Transfer Switches: 2 ms From the Inverter to Bypass, 0 ms Back To Inverter
Back Up Time: 10 min
Buzer UPS In Bypass Condition: INTERMITTENT SOUND WITH 30 SECONDS INTERVALS
Buzer AIR CONDITIONING In Abnormal: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS
Opera Temp: 0-40 ° C
Dimension (DxWxH): 765 x 595 x 1120 mm
Weight: 383 Kg
Description: UPS SIN1502C3
Capacity: 18000 11700 W/VA
AC Voltage: THREE PHASE, 4 WIRE 380 V
AC Frequency: 50 ± 5% Hz
AC Protection: NO FUSE BREAKER
DC Voltage: 192 V
DC INT Battery: 4 x 12 V 24 Ah
DC Protection: NO FUSE BREAKER
CHG: Topology SWITCHING REGULATION
CHG Floating Voltage: 217.6 V
INV Waveform: SINUSOIDA
INV Distorsion:< 3%="">
INV Topology: PULSE WIDTH MODULATION (PWM)
INV Voltage: 220 V ± 2%
INV Frequency: 50 Hz ± 1%
INV Efficiency: ± 85%
Transfer Time When AIR CONDITIONING In Loss: 0 ms
Static Transfer Switches: 2 ms From the Inverter to Bypass, 0 ms Back To Inverter
Back Up Time: 10 min
Buzer UPS In Bypass Condition: INTERMITTENT SOUND WITH 30 SECONDS INTERVALS
Buzer AIR CONDITIONING In Abnormal: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS
Opera Temp: 0-40 ° CBr/> Dimension (DxWxH): 765 x 595 x 1120 mm
Weight: 383 Kg
Description: UPS SIN2002C1
Capacity: 25000 VA/16250 W
AC Voltage: SINGLE PHASE, 3 WIRE 220 V
AC Frequency: 50 ± 5% Hz
AC Protection: NO FUSE BREAKER
DC Voltage: 192 V
DC INT Battery: 4 x 12 V, 38 Ah
DC Protection: NO FUSE BREAKER
CHG Topology: SWITCHING REGULATION
CHG Floating Voltage: 217.6 V
INV Waveform: SINUSOIDA
INV Distorsion:< 3%="">
INV Topology: PULSE WIDTH MODULATION (PWM)
INV Voltage: 220 V ± 2%
INV Frequency: 50 Hz ± 1%
INV: ± 85% Efficiency
Transfer Time When AIR CONDITIONING In Loss: 0 ms
Static Transfer Switches: 2 ms From the Inverter to Bypass, 0 ms Back To Inverter
Back Up Time: 10 min
Buzer UPS In Bypass Condition: INTERMITTENT SOUND WITH 30 SECONDS INTERVALS
Buzer AIR CONDITIONING In Abnormal: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS
Opera Temp: 0-40 ° C
Dimension (DxWxH): 870 x 595 x 1315 mm
Weight: 490 Kg
Description: UPS SIN2002C3
Capacity:25000 VA/16250 W
AC Voltage: THREE PHASE, 4 WIRE 380 V
AC Frequency: 50 ± 5% Hz
AC Protection: NO FUSE BREAKER
DC Voltage: 192 V
DC INT Battery: 4 x 12 V, 38 Ah
DC Protection: NO FUSE BREAKER
CHG: Topology SWITCHING REGULATION
CHG Floating Voltage: 217.6 V
INV Waveform: SINUSOIDA
INV Distorsion:< 3%="">
INV Topology: PULSE WIDTH MODULATION (PWM)
INV Voltage: 220 V ± 2%
INV Frequency: 50 Hz ± 1%
INV: ± 85% Efficiency
Transfer Time When AIR CONDITIONING In Loss: 0 ms
Static Transfer Switches: 2 ms From the Inverter to Bypass, 0 ms Back To Inverter
Back Up Time: 10 min
Buzer UPS In Bypass Condition: INTERMITTENT SOUND WITH 30 SECONDS INTERVALS
Buzer AIR CONDITIONING In Abnormal: INTERMITTENT SOUNDWith 4 SECONDS INTERVAL
Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS
Opera Temp: 0-40 ° C
Dimension (DxWxH): 870 x 595 x 1315 mm
Weight: 490 Kg