We are an official authorized dealer who sold the product UPS ICA.
ICA UPS 1600VA SIN1100C selling.
We also sell Other ICA UPS SIN Series.
ICA TP SERIES
-SIN 1100C 1600VA
-SIN 1500C 2500VA
-SIN 2100C 3100VA
-SIN 3100C 5KVA
-SIN 5100C 8KVA
-SIN 5100C3 8KVA
-SIN 7501C1 10KVA
-SIN 7501C3 10KVA
10-SIN02C1 12.5 KVA
-SIN 1002C3 12.5 KVA
-SIN 1502C1 18KVA
-SIN 1502C3 18KVA
-SIN 2002C1 25KVA
-SIN 2002C3 25KVA
Here's the specs the ICA UPS SIN series:
Description: UPS SIN1100C
Capacity: 1600 VA/1040 W
AC Voltage: 185-250 V
AC Frequency: 50 ± 5% Hz
AC Protection: NO FUSE BREAKER
DC Voltage: 84 V
DC INT Battery: 7 x 12 V, 7 Ah
DC Protection: NO FUSE BREAKER
CHG: Topology SWITCHING REGULATION
CHG Floating Voltage: 95.2 V
INV Waveform: SINUSOIDA
INV Distorsion:< 3%="">
INV Topology: PULSE WIDTH MODULATION (PWM)
INV Voltage: 220 V ± 2%
INV Frequency: 50 Hz ± 1%
INV Efficiency: 85% >
Transfer Time When AIR CONDITIONINGIn Loss: 0 ms
Static Transfer Switches: 2 ms From the Inverter to Bypass, 0 ms Back To Inverter
Back Up Time: 10 min
Buzer UPS In Bypass Condition: INTERMITTENT SOUND WITH 30 SECONDS INTERVALS
Buzer AIR CONDITIONING In Abnormal: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS
Opera Temp: 0-40 ° C
Dimension (DxWxH): 510 x 205 x 450 mm
Weight: 50 Kg
Description: UPS SIN1500C
Capacity: 2500 VA/1625 W
AC Voltage: 185-250 V
AC Frequency: 50 ± 5% Hz
AC Protection: NO FUSE BREAKER
DC Voltage: 120 V
DC INT Battery: 10 x 12 V, 7 Ah
DC Protection: NO FUSE BREAKER
CHG: Topology SWITCHING REGULATION
CHG Floating Voltage: 136 V
INV WavefORM: SINUSOIDA
INV Distorsion:< 3%="">
INV Topology: PULSE WIDTH MODULATION (PWM)
INV Voltage: 220 V ± 2%
INV Frequency: 50 Hz ± 1%
INV Efficiency: 85% >
Transfer Time When AIR CONDITIONING In Loss: 0 ms
Static Transfer Switches: 2 ms From the Inverter to Bypass, 0 ms Back To Inverter
Back Up Time: 10 min
Buzer UPS In Bypass Condition: INTERMITTENT SOUNDWith 30 SECONDS INTERVALS
Buzer AIR CONDITIONING In Abnormal: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS
Opera Temp: 0-40 ° C
Dimension (DxWxH): 610 x 230 x 475 mm
Weight: 74 Kg
Description: UPS SIN2100C
Capacity: 3100 VA/2000 W
AC Voltage: 185-250 V
AC Frequency: 50 ± 5% Hz
AIR CONDITIONING Protection: NO FUSE BREAKER
DC Voltage: 120 V
DC INT Battery: 10 x 12 V, 7 Ah
DC Protection: NO FUSE BREAKER
CHG: Topology SWITCHING REGULATION
CHG Floating Voltage: 136 V
INV Waveform: SINUSOIDA
INV Distorsion:< 3%="">
INV Topology: PULSE WIDTH MODULATION (PWM)
INV Voltage: 220 V ± 2%
INV Frequency: 50 Hz ± 1%
INVEfficiency: 85% >
Transfer Time When AIR CONDITIONING In Loss: 0 ms
Static Transfer Switches: 2 ms From the Inverter to Bypass, 0 ms Back To Inverter
Back Up Time: 10 min
Buzer UPS In Bypass Condition: INTERMITTENT SOUND WITH 30 SECONDS INTERVALS
Buzer AIR CONDITIONING In Abnormal: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS
Opera Temp: 0-40° C
Dimension (DxWxH): 265 x 630 x 610 mm
Weight: 85 Kg
Description: UPS SIN3100C
Capacity: 5000 VA/3250 W
AC Voltage: 185-250 V
AC Frequency: 50 ± 5% Hz
AC Protection: NO FUSE BREAKER
DC Voltage: 192 V
DC INT Battery: 4 x 12 V, 7 Ah
DC Protection: NO FUSE BREAKER
CHG: SWITCHING Topology REGULATIOn
CHG Floating Voltage: 217.6 V
INV Waveform: SINUSOIDA
INV Distorsion:< 3%="">
INV Topology: PULSE WIDTH MODULATION (PWM)
INV Voltage: 220 V ± 2%
INV Frequency: 50 Hz ± 1%
INV Efficiency: 85% >
Transfer Time When AIR CONDITIONING In Loss: 0 ms
Static Transfer Switches: 2 ms From the Inverter to Bypass, 0 ms Back To Inverter
Back Up Time: 10 minBr/> Buzer UPS In Bypass Condition: INTERMITTENT SOUND WITH 30 SECONDS INTERVALS
Buzer AIR CONDITIONING In Abnormal: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS
Opera Temp: 0-40 ° C
Dimension (DxWxH): 630 x 265 x 690 mm
Weight: 110 Kg
Description: UPS SIN5100C
Capacity: 8000 VA/5200 W
AC Voltage: SINGLE PHASE, 3 WIRE 220 V
AC Frequency: 50 ± 5% Hz
AC Protection: NO FUSE BREAKER
DC Voltage: 192 V
DC INT Battery: 4 x 12 V, 2 Ah
DC Protection: NO FUSE BREAKER
CHG: Topology SWITCHING REGULATION
CHG Floating Voltage: 217.6 V
INV Waveform: SINUSOIDA
INV Distorsion:< 3%="">
INV Topology: PULSE WIDTH MODULATION (PWM)r/> INV Voltage: 220 V ± 2%
INV Frequency: 50 Hz ± 1%
INV: ± 85% Efficiency
Transfer Time When AIR CONDITIONING In Loss: 0 ms
Static Transfer Switches: 2 ms From the Inverter to Bypass, 0 ms Back To Inverter
Back Up Time: 10 min
Buzer UPS In Bypass Condition: INTERMITTENT SOUND WITH 30 SECONDS INTERVALS
Buzer AIR CONDITIONING In Abnormal: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS
Opera Temp: 0-40 ° C
Dimension (DxWxH): 648 x 360 x 846 mm
Weight: 240 Kg
Description: UPS SIN5100C3
Capacity: 8000 VA/5200 W
AC Voltage: THREE PHASE, 4 WIRE 380 V
AC Frequency: 50 ± 5% Hz
AC Protection: NO FUSE BREAKER
DC Voltage: 192 V
DC INT Battery: 4x 12 V, 2 Ah
DC Protection: NO FUSE BREAKER
CHG: Topology SWITCHING REGULATION
CHG Floating Voltage: 217.6 V
INV Waveform: SINUSOIDA
INV Distorsion:< 3%="">
INV Topology: PULSE WIDTH MODULATION (PWM)
INV Voltage: 220 V ± 2%
INV Frequency: 50 Hz ± 1%
INV: ± 85% Efficiency
Transfer Time When AIR CONDITIONING In Loss: 0 ms
Static TranSFER Switches: 2 ms From the Inverter to Bypass, 0 ms Back To Inverter
Back Up Time: 10 min
Buzer UPS In Bypass Condition: INTERMITTENT SOUND WITH 30 SECONDS INTERVALS
Buzer AIR CONDITIONING In Abnormal: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS
Opera Temp: 0-40 ° C
Dimension (DxWxH): 648 x 360 x 846 mm
Weight: 240 Kg
Description: UPS SIN7501C1
Capacity: 10000 VA/6500 W
AC Voltage: SINGLE PHASE, 3 WIRE 220 V
AC Frequency: 50 ± 5% Hz
AC Protection: NO FUSE BREAKER
DC Voltage: 192 V
DC INT Battery: 4 x 12 V 17 Ah
DC Protection: NO FUSE BREAKER
CHG: Topology SWITCHING REGULATION
CHG Floating Voltage: 217.6 V
INV Waveform: SINUSOIDALA
INV Distorsion:< 3%="">
INV Topology: PULSE WIDTH MODULATION (PWM)
INV Voltage: 220 V ± 2%
INV Frequency: 50 Hz ± 1%
INV: ± 85% Efficiency
Transfer Time When AIR CONDITIONING In Loss: 0 ms
Static Transfer Switches: 2 ms From the Inverter to Bypass, 0 ms Back To Inverter
Back Up Time: 10 min
Buzer UPS In Bypass Condition: INTERMITTENT SOUND WITH 30 SECONDS INTERVAL
Buzer AIR CONDITIONING In Abnormal: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS
Opera Temp: 0-40 ° C
Dimension (DxWxH): 765 x 595 x 1120 mm
Weight: 307 Kg
Description: UPS SIN7501C3
Capacity: 10000 VA/6500 W
AC Voltage: THREE PHASE, 4 WIRE 380 V
AC Frequency: 50 ± 5% Hz
AIR CONDITIONINGProtection: NO FUSE BREAKER
DC Voltage: 192 V
DC INT Battery: 4 x 12 V 17 Ah
DC Protection: NO FUSE BREAKER
CHG: Topology SWITCHING REGULATION
CHG Floating Voltage: 217.6 V
INV Waveform: SINUSOIDA
INV Distorsion:< 3%="">
INV Topology: PULSE WIDTH MODULATION (PWM)
INV Voltage: 220 V ± 2%
INV Frequency: 50 Hz ± 1%
> INV: ± 85% Efficiency
Transfer Time When AIR CONDITIONING In Loss: 0 ms
Static Transfer Switches: 2 ms From the Inverter to Bypass, 0 ms Back To Inverter
Back Up Time: 10 min
Buzer UPS In Bypass Condition: INTERMITTENT SOUND WITH 30 SECONDS INTERVALS
Buzer AIR CONDITIONING In Abnormal: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS
Temp: Opera0-40 ° C
Dimension (DxWxH): 765 x 595 x 1120 mm
Weight: 307 Kg
Description: UPS SIN1002C1
Capacity: 12500 VA/8125 W
AC Voltage: SINGLE PHASE, 3 WIRE 220 V
AC Frequency: 50 ± 5% Hz
AC Protection: NO FUSE BREAKER
DC Voltage: 192 V
DC INT Battery: 4 x 12 V 24 Ah
DC Protection: NO FUSE BREAKER
CHG Topology: SWITCHING REGULATION
CHG Floating Voltage: 217.6 V
INV Waveform: SINUSOIDA
INV Distorsion:< 3%="">
INV Topology: PULSE WIDTH MODULATION (PWM)
INV Voltage: 220 V ± 2%
INV Frequency: 50 Hz ± 1%
INV: ± 85% Efficiency
Transfer Time When AIR CONDITIONING In Loss: 0 ms
Static Transfer Switches: 2 ms From the Inverter to Bypass, 0 ms Back To Inverter
BACK Up Time: 10 min
Buzer UPS In Bypass Condition: INTERMITTENT SOUND WITH 30 SECONDS INTERVALS
Buzer AIR CONDITIONING In Abnormal: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS
Opera Temp: 0-40 ° C
Dimension (DxWxH): 765 x 595 x 1120 mm
Weight: 364 Kg
Description: UPS SIN1002C3
Capacity: 12500 VA/8125 WBr/> AC Voltage: THREE PHASE, 4 WIRE 380 V
AC Frequency: 50 ± 5% Hz
AC Protection: NO FUSE BREAKER
DC Voltage: 192 V
DC INT Battery: 4 x 12 V 24 Ah
DC Protection: NO FUSE BREAKER
CHG: Topology SWITCHING REGULATION
CHG Floating Voltage: 217.6 V
INV Waveform: SINUSOIDA
INV Distorsion:< 3%="">
INV Topology: PULSE WIDTH MODULATION (PWM)
INV Voltage: 220 V ± 2%
INV Frequency: 50 Hz ± 1%
INV: ± 85% Efficiency
Transfer Time When AIR CONDITIONING In Loss: 0 ms
Static Transfer Switches: 2 ms From the Inverter to Bypass, 0 ms Back To Inverter
Back Up Time: 10 min
Buzer UPS In Bypass Condition: INTERMITTENT SOUND WITH 30 SECONDS INTERVALS
Buzer AIR CONDITIONING In Abnormal: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS
Opera Temp: 0-40 ° C
Dimension (DxWxH): 765 x 595 x 1120 mm
Weight: 364 Kg
Description: UPS SIN1502C1
Capacity: 18000 11700 W/VA
AC Voltage: SINGLE PHASE, 3 WIRE 220 V
AC Frequency: 50 ± 5% Hz
AC Protection: NO FUSE BREAKER
DC Voltage: 192 V
DCINT Battery: 4 x 12 V 24 Ah
DC Protection: NO FUSE BREAKER
CHG: Topology SWITCHING REGULATION
CHG Floating Voltage: 217.6 V
INV Waveform: SINUSOIDA
INV Distorsion:< 3%="">
INV Topology: PULSE WIDTH MODULATION (PWM)
INV Voltage: 220 V ± 2%
INV Frequency: 50 Hz ± 1%
INV: ± 85% Efficiency
Transfer Time When AIR CONDITIONING In Loss:0 ms
Static Transfer Switches: 2 ms From the Inverter to Bypass, 0 ms Back To Inverter
Back Up Time: 10 min
Buzer UPS In Bypass Condition: INTERMITTENT SOUND WITH 30 SECONDS INTERVALS
Buzer AIR CONDITIONING In Abnormal: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS
Opera Temp: 0-40 ° C
Dimension (DxWxH): 765 x 595 x 1120 mm
Weight: 383 Kg
Description: UPS SIN1502C3
Capacity: 18000 11700 W/VA
AC Voltage: THREE PHASE, 4 WIRE 380 V
AC Frequency: 50 ± 5% Hz
AC Protection: NO FUSE BREAKER
DC Voltage: 192 V
DC INT Battery: 4 x 12 V 24 Ah
DC Protection: NO FUSE BREAKER
CHG: Topology SWITCHING REGULATION
CHG Floating Voltage: 217.6 V
> INV Waveform: SINUSOIDA
INV Distorsion:< 3%="">
INV Topology: PULSE WIDTH MODULATION (PWM)
INV Voltage: 220 V ± 2%
INV Frequency: 50 Hz ± 1%
INV: ± 85% Efficiency
Transfer Time When AIR CONDITIONING In Loss: 0 ms
Static Transfer Switches: 2 ms From the Inverter to Bypass, 0 ms Back To Inverter
Back Up Time: 10 min
Buzer UPS In Bypass Condition: INTERMITTENT SOUND WITH 30 SECONDS INTERVALS
Buzer AIR CONDITIONING In Abnormal: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS
Opera Temp: 0-40 ° C
Dimension (DxWxH): 765 x 595 x 1120 mm
Weight: 383 Kg
Description: UPS SIN2002C1
Capacity: 25000 VA/16250 W
AC Voltage: SINGLE PHASE, 3 WIRE 220 V
AIR CONDITIONING FrequENCY.: 50 ± 5% Hz
AC Protection: NO FUSE BREAKER
DC Voltage: 192 V
DC INT Battery: 4 x 12 V, 38 Ah
DC Protection: NO FUSE BREAKER
CHG: Topology SWITCHING REGULATION
CHG Floating Voltage: 217.6 V
INV Waveform: SINUSOIDA
INV Distorsion:< 3%="">
INV Topology: PULSE WIDTH MODULATION (PWM)
INV Voltage: 220 V ± 2%
InV Frequency: 50 Hz ± 1%
INV: ± 85% Efficiency
Transfer Time When AIR CONDITIONING In Loss: 0 ms
Static Transfer Switches: 2 ms From the Inverter to Bypass, 0 ms Back To Inverter
Back Up Time: 10 min
Buzer UPS In Bypass Condition: INTERMITTENT SOUND WITH 30 SECONDS INTERVALS
Buzer AIR CONDITIONING In Abnormal: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDSINTERVAL
Opera Temp: 0-40 ° C
Dimension (DxWxH): 870 x 595 x 1315 mm
Weight: 490 Kg
Description: UPS SIN2002C3
Capacity: 25000 VA/16250 W
AC Voltage: THREE PHASE, 4 WIRE 380 V
AC Frequency: 50 ± 5% Hz
AC Protection: NO FUSE BREAKER
DC Voltage: 192 V
DC INT Battery: 4 x 12 V, 38 Ah
DC Protection:NO FUSE BREAKER
CHG: Topology SWITCHING REGULATION
CHG Floating Voltage: 217.6 V
INV Waveform: SINUSOIDA
INV Distorsion:< 3%="">
INV Topology: PULSE WIDTH MODULATION (PWM)
INV Voltage: 220 V ± 2%
INV Frequency: 50 Hz ± 1%
INV: ± 85% Efficiency
Transfer Time When AIR CONDITIONING In Loss: 0 ms
Static Transfer Switches: 2 ms From the Inverter to Bypass, 0 ms Back To Inverter
Back Up Time: 10 min
Buzer UPS In Bypass Condition: INTERMITTENT SOUND WITH 30 SECONDS INTERVALS
Buzer AIR CONDITIONING In Abnormal: INTERMITTENT SOUND WITH 4 SECONDS INTERVAL
Buzer Battery Low: INTERMITTENT SOUND WITH 1 SECONDS INTERVALS
Opera Temp: 0-40 ° C
Dimension (DxWxH): 870 x 595 x 1315 mm
Weight: 490 Kg
(Prices listed in column haRGA, not actual price)
Contact us immediately to get information about types, prices and the latest stock.
Pt. Trkomindo Main Charites
Email: marketing@trikomkharisma.com
Tags:
ica ups distributor indonesia jakarta mangga dua master dealer authorized dealer ups official ica ica ups the price to sell indonesia up